PRODUCT OVERVIEW
WARNINGS AND PRECAUTIONS
- Correct installation of the hygiene cover ensures accurate readings.
- Using the thermometer without a hygiene cover may cause inaccurate readings.
- Do not submerge the device in any liquids or expose it to direct moisture.
- This thermometer is not intended as a substitute for a doctor's consultation.
- If the condition does not improve consult your doctor.
- This is not an AP or APG product.
- Intended use: The infrared ear thermometer can measure the infrared heat generated by eardrum area and surrounding tissues to reflect patient's body temperature accurately.
- Choking from swallowing hygiene covers and connection ring by children or pets is possible, please keep out of reach of children and pets.
FUNCTIONS
TEMPERATURE ALARM
- If the thermometer detects a body temperature 99.5°F (37.5°C), one long beep will sound followed by three short beeps to warn the user of potential fever.
SWITCHING BETWEEN FAHRENHEIT (°F) AND CELSIUS (°C)
- In 'Power off' mode, press and hold the 'Scan' button.
- Then press the 'On/Mem' button for 3 seconds whilst still holding the scan button. The '°C' will change to '°F'. You can use the same process to change from '°F' back to '°C'.
MEMORY FUNCTION
- Press the 'On/Mem' button again to see the last temperature stored. The thermometer will automatically save the last reading into the memory, if it is within the temperature range of 93.2°F to 108.0°F (34°C to 42.2°C).
INSTALLING THE HYGIENE COVER
Before first use, pull to remove the tab from the battery cover.
Correct installation of the hygiene cover ensures accurate readings. Always use a new and undamaged hygiene cover before each reading.
- Gently twist the probe cap to remove.
- Place a new hygiene cover into the connection ring.
- Insert the thermometer probe into the centre of the hygiene cover and connection ring.
- Push until it is secure. If the hygiene cover did not connect firmly, this icon
will be flashing on the LCD screen. Remove the hygiene cover and re-install.
TAKING A READING
HANDY TIP
Ensure the ear canal is clean.
- Press 'On/Mem' button. The thermometer is ready for use when the ear icon
stops flashing and two short beeps have sounded.
- Gently pull the baby's ear back, straightening the ear canal. Position the probe snugly into the ear canal, ensuring an accurate reading.
- To measure the ear temperature, press the 'Scan' button until there is a long beep.
- The LCD screen will light up automatically after pressing the scan button, and will automatically turn off after 5 seconds.
- The temperature will show clearly on the LCD display.
- To power off, hold down the 'On/Mem' button for approximately 5 seconds, until the LCD screen shows 'o'. The thermometer will automatically shut down after 1 minute if it is however not turned off, helping prolong battery life.
TIPS FOR TAKING AN ACCURATE READING
- Always use a new and undamaged hygiene cover before each reading.
- It is recommended that you measure 3 times in the same ear. If the 3 readings are different, select the highest temperature.
- There is no gender and age limitation for using infrared thermometers.
- Holding the thermometer too long may cause a higher ambient temperature reading.
This could make the body temperature reading lower than it actually is.
HOW TO INTERPRET YOUR READING
Understanding the meaning of your child's temperature.
READING | MEANING |
>96.3° - 99.4°F (>35.7° - 37.4°c) | Acceptable |
>99.4° - 101.3°F (>37.4° - 38.5°c) | Elevated |
>101.3° - 108.0°F (>38.5° - 42.2°c) | Possible High Fever |
REMEMBER if you are concerned about your child's health you should see a doctor. Even in the absence of fever those who exhibit a normal temperature may still need to receive medical attention.
CARE AND CLEANING
The probe is the most delicate part of the thermometer. When cleaning the lens handle with care to avoid damage. If device is accidentally used without a hygiene cover, clean the probe as follows:
- Use a cotton swab (Alcohol 70% concentration) to clean the lens found inside the probe.
- Allow the probe to fully dry for at least 1 minute.
- The thermometer should be stored at temperature between -20°C to +50°C.
- Keep the unit dry and away from any liquids and out of direct sunlight.
- The probe should not be submerged in any liquids.
- If the thermometer is used according to the instructions, periodic re-adjustment is not required. If at any time you question the accuracy of the temperature readings please contact us.
TROUBLESHOOTING
Device stabilization in process
Solution: Wait until stops flashing.
Battery is low and no more readings are possible
Solution: Replace the battery.
Reading before device stabilization
Solution: Wait until stops flashing.
The ambient temperature is not within the range between 50°F ~104°F (10°C and 40°C).
Solution: Allow the thermometer to rest in a room for at least 30 minutes at room temperature: 50°F ~104°F (10°C and 40°C).
Error 5~9, the system is not functioning properly
Solution: Unload the battery, wait for 1 minute and then turn on.
Temperature taken is higher than 108F/42.2C
Solution: Check the integrity of the hygiene cover and take a new temperature reading.
Temperature taken is lower than 93.2F/34C
Solution: Make sure the hygiene cover is clean and take a new temperature reading.
Device can not be powered on to the ready stage
Solution: Insert a new battery.
Clinical repeatability 0.18°C newborn to 1 year old, 0.17°C 1-5years old, 0.15°C 5years+
This product comes with a 12-month warranty.
Manufacture Date as the serial number (please open the battery cover, it is shown on the inside of the device.) Ex. SN:E912A000001, the first "E" is External, the second number "9" is the manufacture year 2009, the third and the fourth number "12" is the manufacture month, the remaining figures are the serial number. Our batch code is XXXXVT.
CHANGING THE BATTERY
This device is supplied with one lithium cell battery (CR2032).
- Unscrew battery cover.
- Flip the battery out with a small screw driver.
- Insert the new battery under the metal hook on the left side and press the right side of the battery down firmly
- Replace the battery cover.
The positive (+) side up and the negative (-) side pointed down.
PRODUCT SPECIFICATION
- Temperature measurement range: 93.2-108°F (34-42.2°C).
- Operating temperature range: 50-104°F (10-40°C), RH<85%.
- Storage temperature range: -20-+50°C, RH 85%.
- Transportation temperature: < than 70°C, RH 95%.
- Atmospheric pressure: 800~1013 hPa.
- Enclosure Rating: IP22.
- Dimensions: 149.1 x 42.5 x 54.9 mm.
- Weight: 79.7 grams including battery.
- Battery life: around 3,000 readings. Enable normal use: 1 year.
- Expected Service Life: 4 years.
- Complies with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part 5: Performance of infra-red ear thermometers (with maximum device), IEC/EN60601-1- 2(EMC),IEC/EN60601-1(Safety) standards.
- Accuracy: 0.4°F (+/-0.2°C) in a temperature range of 95.9-107.6°F (35.5-42°C).
Accuracy of +/-0.3°C (0.5°F) for other temperature ranges. - This thermometer converts the ear temperature to display its "oral equivalent." (according to the result of the clinical evaluation).
SYMBOL DESCRIPTIONS
![]() | Do not reuse. |
CAUTION. | |
![]() | Manufacturer. |
![]() | BF type applied part. |
![]() | Classification for water ingress and particulate matter. |
Distributed by; Distribuido por;
Mayborn USA Inc. dba Mayborn Group
11th Floor, 1010 Washington Boulevard,
Stamford, Connecticut 06910
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Tommee Tippee Digital Ear Thermometer - Thermometer Manual